I.
Product Description
Micro perforated acoustic panel impresses with high sound absorption without it being visible!
Micro is suitable for almost all surfaces, but not for outdoor applications.
Our wooden microperforated acoustic panel is made up of a series of perforations.
Each panel has a machined groove joint for either a seamless or gap joinery.
Microperforated come in 3 standard patterns:
1.8/1.8/0.5mm
2/2/0.5mm
3/3/0.5mm
The first pair of numbers refer to the distance between the two holes, and the last number refers to the hole diameter.
The surface comes in 3 types of finish:
HPL laminate, melamine, and wood veneer.
The base material can be made of MDF,
fire-resistant MDF, eco-friendly MDF, black MDF.
II.
Specifications
Structure |
Basic Material, Finishing & Fleece |
Material |
MDF |
Front Surface |
HPL laminate, Melamine,Wood Veneer |
Standard Dimension |
600mm x 600mm, 600mm x 1200mm, 1200mm x 1200mm, 1200mm x 2400mm |
Standard Thickness |
15mm, 18mm |
Distances of Two Holes |
1.8/1.8mm, 2/2mm, 3/3mm |
Diameter of Holes |
0.5mm |
Standard Patterns |
1.8/1.8/0.5mm, 2/2/0.5mm, 3/3/0.5mm |
Hole Arrangement |
Linear (E), Staggered (V) |
Eco-Friendly Test |
EN 717 = E1 |
Fire-Rated Test |
ASTM E84 = Class A |
NRC |
0.90 |
III.
Eco-Friendly Test: EN 717 = E1
With reference to EN 717-1:2004, analysis was performed by UV-Vis
ISO 16000: 0.05mg/m3 Formaldehyde, 0.13mg/m3 TVOC
With reference to ISO 16000-9:2006/ COR1-2007 & ISO 16000-6:2021 & ISO 16000-3:2022
IV.
Fire-Rated Test : ASTM E84 = Class A
ASTM E84-15b Standard Test Method for Surface Burning Characteristics of Building Materials
V.
NRC : ISO 354 = 0.90
ISO 354:2003 Acoustics-Measurement of Sound Absorption in a Reverberation Room
VI.
Preparation
1.Place of installation must be dry, with temperature no less than 10 degrees Celsius.
2.Humidity level should be kept between 40% to 60%.
3.Our panels must be placed on site for at least 48 hours in order to adapt to environmental conditions.
VII.
Macau auditorium for wall application 2/2/0.5mm